8K Series ProPalette Repair Manual
Analog Board Voltage Test
Purpose
This procedure verifies correct voltages on the ProPalette Analog board.
WARNING: This test requires that the outer housing of the ProPalette
be removed for access to the specified test points while the
equipment has the power turned ON.
Required Tools and Equipment
Multimeter
Test Procedure
With the ProPalette power on, use a multimeter to check the following voltages on the
analog board (Figure 4-14). If any voltage is out of specification, replace the low-voltage
power supply.
TP9 (filament voltage)
TP14 (DAC_VREF)
TP15 (DAC_VREFV)
TP10 (VDD_C)
TP8 (VSS_C)
Test Location
(Figure 4-14)
Figure 4-14. Analog Board voltage test points
95
Troubleshooting and Diagnostics
Reference
Voltage
Location
Specification
TP13
12.7 ±0.4
TP13
5.00 ±0.15
TP4
5.00 ±0.15
TP23
12.0 ±0.4
TP23
-12.0 ±0.6