Panasonic KX-TDE100 Feature Manual page 211

Pure ip-pbx telephone systems
Hide thumbs Also See for KX-TDE100:
Table of Contents

Advertisement

Method
USB
LAN
Modem
(connected to
SLT port)
*1
*1
Remote access must be enabled through system programming when performing on-site programming via modem.
2. Connection Methods for Remote Programming
Method
Off-site modem
On-site modem
Document Version 2009-12
Description
The PC is connected to the PBX via the USB port of a USB
Module attached to a digital proprietary telephone (DPT).
The PC is connected to the PBX via the MNT port of the
IPCMPR/IPCEMPR card.
The PC is connected to a modem, which is then connected to
an SLT port of the PBX. Use the modem to dial the floating
extension number (default: 599) assigned to the analog remote
maintenance feature to access the PBX.
Description
Call the PBX and have the call directed to the floating extension
number (default: 599) assigned to the analog remote
maintenance feature using one of the following methods:
Direct Access: Using the off-site modem, dial a telephone
number with the modem which will direct your call (via Direct
In Line (DIL) or Direct Inward Dialing (DID) distribution) to the
floating extension number assigned to the analog remote
maintenance feature.
DISA: Using a telephone, dial a telephone number which will
direct your call (via DIL or DID distribution) to a floating
extension number used by the Direct Inward System Access
(DISA) feature (® 4.1.8 DISA (Direct Inward System
Access)). Next, dial the floating extension number assigned to
the analog remote maintenance feature. Then access the PBX
with the modem.
Call Transfer: Using a telephone, dial a telephone number
which will direct your call to an operator (or other extension of
the PBX) and request to be transferred to the floating extension
number assigned to the analog remote maintenance feature
(® 3.1.10 Call Transfer). Then access the PBX with the
modem.
The modem is connected to the Serial Interface (RS-232C port)
and also to either an extension port which is assigned as the
DIL/DID destination, or to a CO line directly. AT commands can
be sent to the modem automatically when it is connected to the
Serial Interface (RS-232C port) and can be programmed
beforehand, through system programming, to initialize the
modem. AT commands can also be sent manually in the PT
system programming mode.
13.1.6 PC Programming
Required
Hardware
USB Module
IPCMPR/
IPCEMPR card
RMT card and
user-supplied
modem
Required
Hardware
RMT card and
user-supplied
modem
User-supplied
modem
Feature Manual
211