13.1.2 Paralleled Telephone
[DPT + SLT]
When in the parallel mode, XDP mode of the Super Hybrid port should be turned off through system
programming.
Whether the SLT rings for incoming calls is programmable.
Ring on: Both telephones ring when a call is received, except for when the digital proprietary telephone
(DPT) is in Hands-free Answerback mode (® 8.1.1 Hands-free Answerback) or voice-calling mode
(Alternate Receiving Ring/Voice) (® 9.1.13 Intercom Call).
Ring off: Only the DPT rings when a call is received, however, the SLT can be used to answer the call.
Both telephones cannot engage in calls simultaneously. If one telephone goes off-hook while the other is
on a call, the call is switched to the telephone that goes off-hook. Note, however, that the call will not be
switched when the telephone is:
a.
Being monitored by another extension (® 3.1.6 Call Monitor).
b.
Receiving an Off-hook Call Announcement (OHCA) (® 12.1.3 OHCA (Off-hook Call
Announcement)) or Whisper OHCA (® 20.1.4 Whisper OHCA).
c.
On a conference call (® 3.1.18 Conference, ® 5.1.3 Executive Busy Override, ® 13.1.14 Privacy
Release).
d.
Using Live Call Screening (LCS) or Two-way Record is activated (® 19.1.4 Voice Mail DPT (Digital)
Integration).
[DPT + DPT]
Available Telephones
KX-DT300 series and KX-T7600 series, except KX-T7640
The PSU-M or PSU-L must be installed when Digital XDP connection enables the number of DPTs to
exceed the maximum capacity that the PBX supports.
The following features cannot be used on either the master or slave DPT:
a.
OHCA: A call waiting tone will be heard even if the OHCA feature is set.
b.
USB Module/Bluetooth Module: The DPTs will not function properly if a USB Module or Bluetooth
Module is attached to either DPT. Do not connect a USB Module or Bluetooth Module to either of the
DPTs.
Note
To cancel a Digital XDP connection, disconnect the slave DPT from the master, then disconnect the and
reconnect the master DPT to the PBX.
[DPT + DPT + SLT]
When an SLT is connected to the slave DPT in parallel mode, the SLT acts as a parallel extension of the
master DPT. If connected in XDP mode, the SLT acts as an independent extension.
Installation Manual References
KX-TDE100/KX-TDE200
1.3.3 System Capacity
3.8.2 Parallel Connection of the Extensions
3.8.3 Digital EXtra Device Port (Digital XDP) Connection
KX-TDE600
1.3.3 System Capacity
3.10.2 Parallel Connection of the Extensions
3.10.3 Digital EXtra Device Port (Digital XDP) Connection