Removing the outfeed sensor

1. Press the PS100's power switch to the off position and then unplug the power
cord from the wall outlet.
2. Remove the top cover.
3. Remove the top half of the sealer by unscrewing the four pressure adjustment
bolts.
4. Remove the sealer sensor bracket assembly from the locating dowels and
remove the two countersunk screws to free the sensor.
5. Detach the outfeed sensor terminal block from the board and disconnect the
wires to completely remove the sensor.
To replace the outfeed sensor, complete the steps of this procedure in reverse
order. Install new cable clamps and check sensor adjustment.
Figure 18. Removing the outfeed sensor.
Page 37
loosen four pressure bolts
remove sealer shims
remove outfeed sensor assembly