Removing The Infeed Sensor - Pressure Seal PS 100 Manual

Compact pressure folder and sealer
Table of Contents

Advertisement

Removing the infeed sensor

1. Press the PS100's power switch to the off position and then unplug the power
cord from the wall outlet.
2. Remove the top cover and infeed cover.
3. Remove the two countersunk screws that mount the infeed microswitch bracket
to the underside of the infeed table. Support the switch to prevent it and the two
nuts and washers dropping into the machine. It may help to lift the infeed tray to
gain access to the infeed sensor.
4. Replace the microswitch, ensuring the wires are reconnected correctly.
To replace the infeed microswitch bracket, complete the steps of this procedure in
reverse order. Install new cable clamps if necessary.
lift tray to gain access
Figure 17. Removing the infeed sensor.
Page 36
remove two countersunk screws

Advertisement