Replacing the feed roll and paper separator

Replace the feed roll and paper separator after every 200,000 documents.
Loosen the two securing screws and slide the old feed roll from the shaft. Reverse
the procedure to install a new feed roll.
Using a flat blade screwdriver, pry the old paper separator from the mounting frame,
and install a new one in the frame.

Removing the clutch

The clutch enables the feed roll to feed single sheets.
1. Press the PS100's power switch to the off position and then unplug the power
cord from the wall outlet.
2. Remove the top cover and right side cover.
3. Remove the E-clip located at the right end of the clutch shaft, take off the crinkle
washer and then remove the clutch gear from the shaft.
4. Disconnect the cable to the clutch and remove the clutch.
To replace the clutch, complete the steps of this procedure in reverse order. A spot
of light oil or grease applied to the clutch gear bearing can prevent squeal
developing in this area.
clutch
clutch gear
Figure 13. Removing the clutch.
Page 31
remove crinkle washer
remove retaining ring