Replacing the sealer
The PS100's sealing rollers, bearings and bearing blocks are replaceable.
Removing the sealer:
1. Press the PS100's power switch to the off position and then unplug the power
cord from the wall outlet.
2. Remove the top cover, outfeed panel, and the right and left side covers.
3. Remove the second fold plate.
4. Remove the motor chain by disconnecting the link and then remove the infeed
sprocket, outfeed sprocket and chain.
5. Disconnect the outfeed sensor from the circuit board.
6. While supporting the sealing roller assembly, remove the eight screws (four per
side) that mount it to the PS100's chassis. Remove the assembly and set it
aside.
When installing the replacement sealer module, complete the steps of this
procedure in reverse order.
Adjusting the sealing roller pressure
The process of removing lodged documents by releasing the sealing roller pressure
is covered in the operator's manual.
lift out sealer unit
Figure 15. Replacing the sealer.
Page 34
remove retaining screws