Canon iR2030 Series Service Manual page 315

Ir2030/2025/2022/2018 series
Hide thumbs Also See for iR2030 Series:
Table of Contents

Advertisement

No.
Tx/Rx
Description
##0282
[Tx]
at time of transmission, the procedural signal has been transmitted more than specified.
##0283
[Tx]
at time of transmission, the procedural signal has been transmitted more than specified.
##0284
[Tx]
at time of transmission, DCN is received after transmission of TCF.
##0285
[Tx]
at time of transmission, DCN is received after transmission of EOP.
##0286
[Tx]
at time of transmission, DCN is received after transmission of EOM.
##0287
[Tx]
at time of transmission DCN is received after transmission of MPS.
##0288
[Tx]
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0289
[Tx]
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0290
[Tx]
after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0670
[Tx]
at time of V.8 late start, the V.8 ability of DIS front the receiving party is expected to be detected, and the CI signal is expected
to be transmitted in response; however, the procedure fails to advance, and the line is released because of T1 time-out.
##0671
[Rx]
at time of V.8 arrival, procedure fails to move to phase 2 after detection
releasing line
##0672
[Tx]
at time of V.34 transmission, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release
the line and suffer T1 timeout.
##0673
[Rx]
at time of V.34 reception, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release the
line and suffer T1 timeout.
##0674
[Tx]
at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing
the machine to release the line and suffer T1 timeout.
##0675
[Rx]
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing the
machine to release the line and suffer T1 timeout.
##0750
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-NULL, causing the procedural signal
to be transmitted more than specified.
##0752
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-NULL.
##0753
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL,
or T5 time-out (60 sec) has occurred.
##0754
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL.
##0755
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-MPS, causing the procedural signal to
be transmitted more than specified.
##0757
[Tx]
at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
##0758
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS, or
T5 time-out (60 sec) has occurred.
##0759
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS.
##0760
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOM, causing the procedural signal to
be transmitted more than specified.
##0762
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOM.
##0763
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS, or
T5 time-out (60 sec) has occurred.
##0764
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOM.
##0765
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOP, causing the procedural signal to
be transmitted more than specified.
##0767
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOP.
##0768
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP, or
T5 time-out (60 sec) has occurred.
##0769
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP.
##0770
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-NULL, causing the procedural signal
to be transmitted more than specified.
##0772
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-NULL.
##0773
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-NULL,
or T5 time-out (60 sec) has occurred.
##0774
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-NULL.
##0775
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-MPS, causing the procedural signal to
be transmitted more than specified.
##0777
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-MPS.
##0778
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission EOR-MPS, or
T5 time-out (60 sec) has occurred.
##0779
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-MPS.
##0780
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOM, causing the procedural signal
to be transmitted more than specified.
##0782
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOM.
##0783
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-EOM,
or T5 time-out (60 sec) has occurred.
##0784
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOM.
##0785
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOP, causing the procedural signal to
be transmitted more than specified.
##0787
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOP.
##0788
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-EOP, or
T5 time-out (60 sec) has occurred.
##0789
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOP.
##0790
[Rx]
at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
##0791
[Tx/Rx]
while ECM mode procedure is under way, a signal other than a meaningful signal is received.
##0792
[Rx]
at time of ECM reception, PPS-NULL cannot be detected over partial page processing.
of CM signal from caller, causing T1 time-out and
Chapter 14