Chapter 8
2) Remove the fixing pressure release lever [2].
- Resin ring [1]
When installing the fixing pressure release lever, check that the rib [3] of the
lever is inside the pressure block [4].
3) Release the fixing unit harness [2] from the wire saddle [1].
[2]
4) Remove the fixing paper guide [2].
- Screw [1], 1 pc.
[1]
8-10
[2]
[1]
F-8-17
[4]
[3]
F-8-18
[1]
F-8-19
[2]
F-8-20
5) Remove the right side stay [1] and left side stay [2].
- Screw [1], 2 pcs.
[3]
[1]
6) Disconnect the connector [1] and release the fixing DC harness [2] from
the harness guide [3]. Unhook the claw [4] and remove the sensor holder
[5].
- Screw [6], 2 pcs.
[5]
[1]
[6]
[4]
When installing the electrode plate [1], place it under the three claws [2] as
shown below.
[1]
[2]
F-8-21
[2]
[3]
[6]
F-8-22
[2]
F-8-23