Step
Check
8
Is the bridge unit drive motor connected properly?
9
Perform a print test.
Does the error still occur?
10
Perform a print test.
Does the error still occur?

282.01 Sensor (finisher media entrance) static jam A

Step
Check
1
Check the sensor (finisher media entrance) for proper
operation.
Perform the sensor (finisher media entrance) test.
1. Enter the Diagnostics Menu.
2. Touch FINISHER TESTS.
3. Touch Sensor Test.
4. Touch Media Path 1.
5. Touch Fin media ent.
Detach the finisher from the MFP.
Insert a sheet of white media into the finisher media
path entrance.
Does the display change every time a piece of white
media is placed over the sensing area of the above
sensor?
Yes
No
Replace the
Replace the
bridge unit drive
connection.
motor.
Go to
"Bridge
unit drive motor
assembly
removal" on
page
4-90.
Replace the
Problem solved.
bridge unit
interface card
assembly.
Go to
"Bridge
unit interface
card assembly
removal" on
page
4-194.
Go to step 10.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-195.
Yes
No
Go to step 3.
Go to step 2.