7500-XXX
Power supply and interlock
The finisher is equipped with the following interlock switches.
•
Switch (finisher front door interlock)–Turns off when the cover assembly front opens, shutting off the
Interlock +24 V dc line in the finisher.
•
Switch (eject cover interlock)–Turns off when the cover eject on the right side opens, shutting off the
Interlock +24 V dc line in the finisher.
AC
Printer
1-50
Options Service Manual
Finisher
controller
card asm
+5 V dc
Finisher LVPS
card asm
+24 V dc
+24 V dc
ON/OFF
Interlock
+24 V dc
Switch (eject cover interlock)
Switch (finisher front door interlock)
Sensor
Switch
(eject cover
interlock)
Switch
(finisher
front door
interlock