Sensor (Bridge Unit Media Entrance) Static Jam A - Lexmark X850e Service Manual

Hide thumbs Also See for X850e:
Table of Contents

Advertisement

Step
Check
6
Check the bridge unit drive motor connection.
Is the above motor properly connected?
7
Perform a print test.
Does the error still occur?
8
Perform a print test.
Does the error still occur?

280.01 Sensor (bridge unit media entrance) static jam A

Step
Check
1
Perform the sensor (bridge unit media entrance) test.
1. Enter the Diagnostics Menu.
2. Touch FINISHER TESTS.
3. Touch Sensor Test.
4. Touch Media Path 1.
5. Touch Bridge media ent.
Open the bridge unit top cover assembly.
Does the operator panel display change every time the
actuator of the sensor (bridge unit media entrance) is
operated?
2
Check the sensor (bridge unit media entrance)
connection
Is the above sensor connected properly?
Yes
No
Replace the
Replace the
bridge unit drive
connection.
motor.
Go to
"Bridge
unit drive motor
assembly
removal" on
page
4-90.
Replace the
Problem solved.
bridge unit
interface card
assembly.
Go to
"Bridge
unit interface
card assembly
removal" on
page
4-194.
Go to step 8.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-195.
Yes
No
Go to step 3.
Go to step 2.
Replace the
Replace the
sensor (bridge
connection.
unit media
entrance).
"Sensor
Go to
(bridge unit
media entrance)
removal" on
page
4-93.
Diagnostic information
7500-XXX
2-59

Advertisement

Table of Contents
loading

This manual is also suitable for:

X852eX854eX860deX862deX864de

Table of Contents