2.1.2 Pressure and temperature of refrigerant

Capillary Tube
The pressure in normal condition shows the figure in the right side
table, but the pressure (P1) of high pressure side tube is affected
greatly by the temperature change and about 16kg/cm
temperature condition (indoor/outdoor 21°C).
The pressure fluctuation is affected by the tube length or insulation
as well as temperature change, so measure the pressure (P
pressure side for the trouble shooting of refrigerant system.
Pressure
(than normal)
Higher
Lower
Note) The high/low temperature is a figure converted into pressure.
The low pressure is normally 4.5-6.0kg/cm
(Temperature is normally 3°C-10°C.)
TCL Air Conditioner Service Manual
High pressure (Liquid side)tube
Low pressure(Gas side) tube
<Trouble finding by pressure/temperature>
Temperature
(than normal)
Bad compression:
Compressor failure, Bad revers-
Higher
ing Valve
Cooling load is small.
Normal
Liquid refrigerant suction:
Excessive refrigerant charging
Gas short : Gas leak
Higher
Closed : Pipe internal
2
P
1
P
2
Accumulator
.G in a low
2
) of low
2
Cause
G.
9
Compressor
Measuring place
Pressure(kg/cm
P1
P2
Explanation
Current flows weakly.
Current flows weakly.
High pressure is not
increased rapidly in early
running stage.
Current is low.
Current is low.
G)
2
About19.5
About 5.0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.

This answer is automatically generated

Table of Contents

Save PDF