Main Differences Between R-407C And R22 Refrigerant - TCL TAC-07CS Service Manual

Wall mounted split-type air conditioners
Table of Contents

Advertisement

2 Main differences between R-407c and R22 refrigerant

R-407c
{
R32
23%
R-407c
R125
25%
R-134a 52%
NOT PERMITTED!
Only complete refrigerant charge
Use only HFC detector
TCL Air Conditioner Service Manual
1. Refrigerant charging procedure
2. Refrigerant composition
3. Partial refrigerant charge
4. Leak detector
5. Temperature trend in evaporate
6. Temperature trend in condenser
2
R-22
YES!
Possible partial refrigerant charge
Use only HCFC detector

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.