Wiring Diagram - Tac-24Chs/K, Tac-24Chsc/K - TCL TAC-07CS Service Manual

Wall mounted split-type air conditioners
Table of Contents

Advertisement

Mode No.: TAC-24CHS/K, TAC-24CHSC/K
INDOOR UNIT
White
Red
Yellow
Blue
Brown
Yellow/Green
To Outdoor Unit
OUTDOOR UNIT
Yellow/Green
White
Red
Yellow
White
Brown
Yellow/Green
Brown
Blue
TCL Air Conditioner Service Manual
White
1
Red
2
O.FAN
Yellow
3
VAL
Blue
N
AC(N)
Brown
L
Yellow/Green
White
1
Red
2
Blue
Blue
3
White
4-way Vane
N
Brown
L
Yellow/Green
L
N
Blue
Brown
Pipe Temp. Sensor
PCB
N.O
COM
1
2
Display PCB
Fan Capacitor
C1
FM
Fan Motor
Relay
28
Transformer
FM
Fan Motor
5
4
SM
3
2
1
5
4
SM
3
2
1
Vane Motor
3
4
Room Temp. Sensor
Pipe Temp. Sensor
Blue
Compressor
Capacity
White
C S R
FM
Compressor
Motor
Blue
C2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.

This answer is automatically generated

Table of Contents