Model No.
Type
Control type
Rated cooling capacity
Rated heating capacity
EER for cooling
COP for heating
Moisture removal
High
Indoor noise level at
Med.
cooling
Low
Outdoor noise level
Electrical Data
Power supply
Voltage Range
Cooling
Rated current
Heating
Cooling
Rated input
Heating
Refrigerating System
Refrigerant/Charge
Type
Model
Compressor
LRA
MFG
Evaporator
Condenser
Expansion device
Defrosting system
Fan System
Indoor air circulation
Indoor fan type
Cooling
Indoor
fan
speed
Heating
H/M/L
Dry
Sleep
Indoor fan motor output
Outdoor air circulation
Outdoor fan type
Outdoor fan speed
Outdoor fan motor output
Connections
Refrigerant coupling
Gas
Connecting Pipe
Liquid
Size
Connecting Wiring
number
Drainage Pipe
Others
Suitable area
Net dimensions
Indoor
(W x H x D)
Outdoor
Indoor
Net weight
Outdoor
Packing dimensions
Indoor
(W x H x D)
Outdoor
Indoor
Gross weight
Outdoor
Loading Capacity
40'/40'HC
TCL Air Conditioner Service Manual
TAC-07CSC/K
Cooling Only
Remote
Btu/h
7,000
Btu/h
N/A
Btu/h.w
11.0
W/W
N/A
Liters/h
0.8
dB(A)
38
dB(A)
36
dB(A)
32
dB(A)
50
V
198~264
A
4.1
A
N/A
W
880
W
N/A
Gram
R407C/700g
Rotary
------------------
A
------
-----------------
3
m
/h
480
Cross flow
rpm
1230/1150/1000
rpm
N/A
rpm
1000
rpm
1000
W
12
3
m
/h
---
Propeller fan
rpm
860
W
31
Inches
7/16
Inches
3/4
¡Á
Core
2
m
12~19
mm
770¡Á250¡Á179
mm
700¡Á255¡Á540
kg
8.0
kg
31
mm
863¡Á325¡Á270
mm
803¡Á380¡Á598
kg
10
kg
35
111/238/276
4
TAC-07CHSC/K
TAC-09CSC/K
Heating Pump
Remote
7,000
7,500
11.0
3.2
0.8
38
36
32
50
220-240V~/50Hz
198~264
4.1
4.1
880
880
R407C/700g
Rotary
-----------------
-------
-----------------
Louver fin and Grooved tube type (¦Õ7)
Corrugated fin and Grooved tube type (¦Õ9.53)
Capillary tube
Microcomputer controlled reverse system
480
Cross flow
1230/1150/1000
1230/1150/1000
1230/1150/1000
1000
1000
12
---
Propeller fan
860
31
Flare type
7/16
3/4
O.D 16mm
12~19
770¡Á250¡Á179
770¡Á250¡Á179
700¡Á255¡Á540
700¡Á255¡Á540
8.0
32
863¡Á325¡Á270
863¡Á325¡Á270
803¡Á380¡Á598
803¡Á380¡Á598
10
36
111/238/276
TAC-09CHSC/K
Cooling Only
Heating Pump
Remote
Remote
9,000
9,000
N/A
9,500
11.0
11.0
N/A
3.2
0.8
0.8
38
38
36
36
32
32
50
50
198~264
198~264
4.1
4.1
N/A
4.1
880
880
N/A
880
R407C/700g
R407C/700g
Rotary
Rotary
------------------
------------------
------
------
----------------
-----------------
480
480
Cross flow
Cross flow
1230/1150/1000
1230/1150/1000
N/A
1000
1000
1000
1000
12
12
---
---
Propeller fan
Propeller fan
860
860
31
31
3/4
3/4
7/16
7/16
12~19
12~19
770¡Á250¡Á179
700¡Á255¡Á540
8
8
31
32
863¡Á325¡Á270
803¡Á380¡Á598
10
10
35
36
111/238/276
111/238/276

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.