TCL TAC-07CS Service Manual page 7

Wall mounted split-type air conditioners
Table of Contents

Advertisement

Model No.
Type
Control type
Rated cooling capacity
Rated heating capacity
EER for cooling
COP for heating
Moisture removal
High
Indoor noise level at
Med.
cooling
Low
Outdoor noise level
Electrical Data
Power supply
Voltage Range
Cooling
Rated current
Heating
Cooling
Rated input
Heating
Refrigerating System
Refrigerant/Charge
Type
Model
Compressor
LRA
MFG
Evaporator
Condenser
Expansion device
Defrosting system
Fan System
Indoor air circulation
Indoor fan type
Cooling
Indoor
fan
speed
Heating
H/M/L
Dry
Sleep
Indoor fan motor output
Outdoor air circulation
Outdoor fan type
Outdoor fan speed
Outdoor fan motor output
Connections
Refrigerant coupling
Gas
Connecting Pipe
Liquid
Size
Connecting Wiring
number
Drainage Pipe
Others
Suitable area
Indoor
Net dimensions
(W x H x D)
Outdoor
Indoor
Net weight
Outdoor
Packing dimensions
Indoor
(W x H x D)
Outdoor
Indoor
Gross weight
Outdoor
Loading Capacity
40'/40'HC
Note: The technical specifications is only reference.
TCL Air Conditioner Service Manual
TAC-24CS/K
Cooling Only
Remote
Btu/h
24,000
Btu/h
N/A
Btu/h.w
9.0
W/W
N/A
Liters/h
2.2
dB(A)
47
dB(A)
44
dB(A)
40
dB(A)
58
V
198~264
A
13
A
N/A
2600
W
W
N/A
Gram
R22/2500g
Rotary
------------------
A
------
-----------------
3
m
/h
1000
Cross flow
rpm
1300/1200/1100
rpm
N/A
rpm
1000
rpm
1000
W
35
3
m
/h
---
Propeller fan
rpm
850
W
110
Inches
7/8
Inches
5/8
¡Á
Core
2
m
35~48
mm
1036¡Á313¡Á204
mm
890¡Á307¡Á660
kg
16
kg
57
mm
1103¡Á395¡Á280
mm
990¡Á405¡Á705
kg
20
kg
63
66/142/162
7
TAC-24CHS/K
TAC-24CSC/K
Cooling Only
Heating Pump
Remote
24,000
26,000
9.0
2.55
2.2
47
44
40
58
220-240V~/50Hz
198~264
13
13.8
2600
2800
R22/2500g
Rotary
-----------------
-------
-----------------
Louver fin and Grooved tube type (¦Õ7)
Corrugated fin and Grooved tube type (¦Õ9.53)
Capillary tube
Microcomputer controlled reverse system
1000
Cross flow
1300/1200/1100
1300/1250/1150
1300/1200/1100
1000
1000
35
---
Propeller fan
850
110
Flare type
7/8
5/8
O.D 16mm
35~48
1036¡Á313¡Á204
1036¡Á313¡Á204
890¡Á307¡Á660
890¡Á307¡Á660
16
60
1103¡Á395¡Á280
1103¡Á395¡Á280
990¡Á405¡Á705
990¡Á405¡Á705
20
65
66/142/162
TAC-24CHSC/K
Heating Pump
Remote
Remote
24,000
24,000
N/A
26,000
9.2
9.2
N/A
2.8
2.2
2.2
47
47
44
44
40
40
58
58
198~264
198~264
11.8
11.8
N/A
11.8
2600
2600
N/A
2600
R407C/2540g
R407C/2540g
Rotary
Rotary
------------------
------------------
------
------
----------------
-----------------
1000
1000
Cross flow
Cross flow
1300/1250/1150
N/A
1300/1250/1150
1150
1150
1150
1500
35
35
---
---
Propeller fan
Propeller fan
850
850
85
85
7/8
7/8
5/8
5/8
35~48
35~48
1036¡Á313¡Á204
890¡Á307¡Á660
16
16
57
60
1103¡Á395¡Á280
990¡Á405¡Á705
20
20
63
65
66/142/162
66/142/162

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.