5. The term of unit

1) Kcal : Adding or releasing heat to or from a substance changes its temperature. This change of temperature is
in proportion the heat added or released. This heat is called calorie which is expressed in Kcal or cal.
1 Kcal is equal to the amount of heat required to raise the 1°C temperature of 1kg water 4°C.
2) BTU : 1 BTU is equal to the amount of heat required to raise the 1°F temperature of 1 lb water.
• 1 Kcal = 3.968 BTU, 1 BTU = 0.252 Kcal
3) RT : 1 RT (Refrigerating Ton) is equal to the capacity which makes 1 Ton water 0°C into ice 0°C in 24 hours. It
is expressed in calorie required to freeze water 1 Ton water 32°F(2000 lb) into ice 32°F, and when using
the solidification latent heat of water, 1RT is as follows
• 1 RT = 144BTU/lb x 2000 lb/24hr = 12,000 BTU/hr = 3,024 Kcal/hr = 3.517 KW
4) Hp : Horse Power
• 1 Hp = 0.75 KW = 645 Kcal/h,
5) Temperature conversion (°C
• °F = 9/5°C + 32,
6) Area or volume conversion
• 1m
= 10.764 ft
2
7) Weight conversion
• 1Kg = 2.2 lb,
8) Unit conversion table
Classification
BTU/h
1BTU/h
1Kcal/h
1W
1KJ
1Hp
1RT
12000
TCL Air Conditioner Service Manual
1W = 0.86 Kcal/h
°F)
°C = 5/9 (°F-32)
,
1m
= 35.3165 ft
2
3
3
1 lb = 0.45 Kg
Kcal/h
1
0.252
3.968
1
3.413
0.86
0.948
0.239
2559
645
3024
W
KJ
0.293
1.055
1.163
4.186
1
3.601
0.278
1
750
2700
3516
12660
6
Hp
RT
0.00039
0.000083
0.00155
0.000329
0.00133
0.000283
0.00037
0.000079
1
0.212
4.68
1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.

This answer is automatically generated

Table of Contents

Save PDF