Parts List: Outdoor Unit - Tac-18Chs/K - TCL TAC-07CS Service Manual

Wall mounted split-type air conditioners
Table of Contents

Advertisement

Outdoor Unit- TAC-18CHS/K
No.
Part No.
1
1080050026
2
1080050011
3
1210500107
4
1080050004
5
1170040054
6
1070030012
7
1080050001
8
1080050009
9
1080320112
10
1213590201
11
---------------
12
1210500102
13
1210500106
14
1120120016
15
1080050003
16
1120130021
17
1080050002
18
1073551103
19
1080020002
20
1080010006
21
1170100007
22
1170100027
23
1170200020
24
1073570503
25
1073570502
26
1173570501
27
1173570502
28
1174561802
29
1190070020
30
1190070002
31
1190070021
32
1190070022
TCL Air Conditioner Service Manual
Part Name
Grille
Top Cover
Condenser
Outdoor Motor Supporter
Outdoor Motor
Propeller Fan
Left Plate
Front Plate
Fan Guard
Capillary Assembly
Compressor and its Accessories
4-way Vane assembly
Base
Two-way Valve
Valve Supporter
Three-way Valve
Right Plate
Electrical Box Cover
Electrical Parts Box
Capacitor Strip
Compressor Capacitor
Fan Motor Capacitor
Terminal
Up Cable Clamp
Lower Cable Clamp
Compressor
Power
Wiring
Earthing Wiring
Outdoor Pipe Sensor
Base Carton
Cabinet Carton
Base Foaming
Cover Forming
Q'ty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Supply
1
1
1
1
1
1
1
50
Remark
Optional
Not shown in the Explosion
view.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.

This answer is automatically generated