“Dry” Mode Operation; “Heating” Mode Operation (Only Available For Heat Pump) - TCL TAC-07CS Service Manual

Wall mounted split-type air conditioners
Table of Contents

Advertisement

Room Temp.
Set TEMP. £ « 1 ¡ æ
Set TEMP. £ - 1 ¡ æ
Time
Indoor Fan
Compressor
Outdoor Fan
4. "DRY" Mode Operation
(1) The system for DRY operation used the same refrigerant circle as the cooling circle.
(2) When the system operates in DRY mode ,at first it operates in cooling mode at 18 ¡ æ
then, the system operates in cooling mode with low speed that regards the temperature of the room
temperature sensor reads decrease 2¡ æ
setted operation is failing but the vane motor can be controlled.
5. "HEATING" Mode Operation (Only available for Heat Pump)
(1) When the HEATING mode is selected without setting temperature, the system will set the temperature at 23
¡ æ
automatically with the AUTO FAN speed.
(2) When selecting the HEATING mode operation, the system will operate according to the setting by the
remote controller and the operation is as following:
Set Temp. £ « 1 ¡ æ
Set Temp. £ - 1 ¡ æ
Room Temp.
Time
Compressor
Outdoor fan
(3) In HEATING mode, the indoor fan motor is controlled by Cold Air Prevention Control.
(4) Cold Air Prevention Control
The function is intend to prevent cold air from being discharged when the heating operation starts or
when defrosting.
The indoor fan speed will be controlled as following:
The vane angle is at the angle C(100¡ ã ).
34 ¡ æ
30 ¡ æ
27 ¡ æ
25 ¡ æ
23 ¡ æ
TCL Air Conditioner Service Manual
More than 2 min
More than 2 min
Set Speed
Set Speed
ON
OFF
ON
OFF
More than 2 min
More than 2 min
ON
OFF
ON
OFF
OFF
UL
More than 2 min
Set Speed
ON
ON
as the set temperature. During the course of this, the fan speed
More than 2 min
ON
ON
Set Speed
18
More than 2 min
More than 2 min
Set Speed
Set Speed
OFF
ON
OFF
ON
for 3 minutes, and
More than 2 min
More than 2 min
OFF
ON
OFF
ON
UL OFF
UL

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAC-07CS and is the answer not in the manual?

Questions and answers

JAVIER
April 4, 2025

Cual es la conexión de la entrada de corriente de split tcl

1 comments:
Mr. Anderson
April 4, 2025

The power input connection for the TCL TAC-07CS split air conditioner is as follows:

- For the indoor unit: Connect terminals 1 (WHITE), 2 (BLUE), and 3 (BROWN) to the corresponding terminals on the outdoor unit.
- The power supply connects to terminals L (BROWN) and N (BLUE) on the indoor unit.
- A GREEN/YELLOW wire is used for grounding.
- A 25A circuit breaker or time delay fuse should be installed between the main power source and the unit if a power plug is not used.