Daikin E-Series Service Manual page 28

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

SiENBE18-621
Model
Rated Capacity
Front Panel Color
m³/min
Air Flow Rates
(cfm)
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
External Static Pressure
Heat Insulation
Liquid
Piping Connection
Gas
Drain
Drawing No.
Note:
The operating sound is based on the rear side suction inlet and the external static pressure 30 Pa.
Operating sound for under side suction inlet : [operating sound for rear side suction inlet] +6 dB.
However, when installation to which the external static pressure becomes low is carried out,
6 dB or more may go up.
Specifications
FDXS25EAVMB
Cooling
2.5kW Class
H
8.7 (307)
M
8.0 (282)
L
7.3 (258)
SL
6.2 (219)
Sirocco Fan
W
Steps
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
A
0.48
W
71
%
64.3
Microcomputer Control
mm
200×700×620
mm
274×906×751
kg
kg
dBA
35/33/31/29
Pa
Both Liquid and Gas Pipes
φ
mm
φ
mm
φ
mm
VP20 (O.D.
3D051881A
Heating
8.7 (307)
8.0 (282)
7.3 (258)
6.2 (219)
62
0.48
71
64.3
21
29
35/33/31/29
30
6.4
9.5
φ
26 / I.D.
20)
FDXS35EAVMB
Cooling
Heating
3.5kW Class
8.7 (307)
8.7 (307)
8.0 (282)
8.0 (282)
7.3 (258)
7.3 (258)
6.2 (219)
6.2 (219)
Sirocco Fan
62
5 Steps, Silent, Auto
Removable-Washable-Mildew Proof
0.48
0.48
71
71
64.3
64.3
Microcomputer Control
200×700×620
274×906×751
21
29
35/33/31/29
35/33/31/29
30
Both Liquid and Gas Pipes
φ
6.4
φ
9.5
φ
φ
VP20 (O.D.
26 / I.D.
20)
3D051883A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
50Hz 230V
17