R - 4 • Slim unit with super silent and greater air flow • Daikin remote controls give you easy control at your fingertips. • Ideal for shops, restaurants or offices requiring maximum floor space • The wired remote control provides you with a schedule timer, for furniture, decorations and fittings enabling to program the air conditioning daily or weekly.
• Indoor Units • R-410A • FHQ-BVV1B Specifications 2-2 TECHNICAL SPECIFICATIONS FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Standard Item Installation and operation manual Accessories Quantity Item Paper pattern for installation Drain hose Clamp metal Insulation for fitting Sealing pad Clamps...
• Indoor Units • R-410A • FHQ-BVV1B Options FHQ∼B Name of option Remark Replacement long-life filter KAF501DA80 KAF501DA112 KAF501DA160 Drain up kit KDU50N125VE L-type piping kit (for upward direction) KHFP5MA160 Remote control Wired type BRC1D528 Infrared type For Heat pump BRC7EA63W For cooling only BRC7EA66...
• Indoor Units • R-410A • FHQ-BVV1B Control systems BRC1D52 5 x 10 (Round end slit) 6.5 x 9 (Round end slit) HoleJ5 5 x 7 (Round end slit) Cover closed 3TW23651-2 Cover open • Split Sky Air • Indoor Units...
• Indoor Units • R-410A • FHQ-BVV1B Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FHQ35B Position slit hole for taking out in piping back (View from the front) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) 30 or more 30 or more...
Page 11
• Indoor Units • R-410A • FHQ-BVV1B Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FHQ60B Position slit hole for taking out in piping back (View from the front) (Hanging position) Hanging bolt Position: hole of wall for taking out in piping back (View from the front) 30 or more 30 or more...
Page 12
• Indoor Units • R-410A • FHQ-BVV1B Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FHQ100B Position slit hole for taking out in piping back (View from the front) Hanging bolt (Hanging position) Position: hole of wall for taking out in piping back (View from the front) 30 or more 30 or more...
• Indoor Units • R-410A • FHQ-BVV1B Wiring diagram 8 - 1 Wiring diagram FHQ35∼60B Connecter discrimination colour for components. In case of simultaneous operation system. Connecter colour for components. Connecter colour for printed circuit board. Notes Indoor unit Indoor unit To outdoor (master) (slave)
• Indoor Units • R-410A • FHQ-BVV1B Wiring diagram 8 - 2 External connection diagram NOTES Line voltage wiring Control circuit wiring All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. Use copper conductors only.
• Indoor Units • R-410A • FHQ-BVV1B Sound data 9 - 2 Sound pressure spectrum FHQ35B FHQ50B H (230V) H (230V) L (230V) L (230V) approximate approximate threshold hearing threshold hearing for continuous for continuous noise noise 4D028280B 4D028281B Octave band center frequency (Hz) Octave band center frequency (Hz) NOTES NOTES...
Page 18
• Indoor Units • R-410A • FHQ-BVV1B Sound data 9 - 2 Sound pressure spectrum FHQ100B FHQ125B approximate threshold approximate threshold hearing for continuous hearing for continuous noise noise 4D028284B 4D028283B Octave band center frequency (Hz) Octave band center frequency (Hz) NOTES NOTES Operation sound is measured in an anechoic...
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ35∼50B Cooling - air velocity distribution Air flow direction: horizontal FHQ35∼50B Cooling - air temperature distribution Air flow direction: horizontal 4D028550 • Split Sky Air • Indoor Units...
Page 20
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ60-71B Cooling - air velocity distribution Air flow direction: horizontal FHQ60-71B Cooling - air temperature distribution Air flow direction: horizontal 4D028551B • Split Sky Air • Indoor Units...
Page 21
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ100B Cooling - air velocity distribution Air flow direction: horizontal FHQ100B Cooling - air temperature distribution Air flow direction: horizontal 4D028552B • Split Sky Air • Indoor Units...
Page 22
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ125B Cooling - air velocity distribution Air flow direction: horizontal FHQ125B Cooling - air temperature distribution Air flow direction: horizontal 4D028553B • Split Sky Air • Indoor Units...
Page 23
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ35∼50B Heating - air velocity distribution Air flow direction: 45° (downward) FHQ35∼50B Heating - air temperature distribution Air flow direction: 45° (downward) 4D028554 • Split Sky Air • Indoor Units...
Page 24
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ60-71B Heating - air velocity distribution Air flow direction: 45° (downward) FHQ60-71B Heating - air temperature distribution Air flow direction: 45° (downward) 4D028555B • Split Sky Air • Indoor Units...
Page 25
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ100B Heating - air velocity distribution Air flow direction: 45° (downward) FHQ100B Heating - air temperature distribution Air flow direction: 45° (downward) 4D028556B • Split Sky Air • Indoor Units...
Page 26
• Indoor Units • R-410A • FHQ-BVV1B Air flow pattern FHQ125B Heating - air velocity distribution Air flow direction: 45° (downward) FHQ125B Heating - air temperature distribution Air flow direction: 45° (downward) 4D028557B • Split Sky Air • Indoor Units...
Page 27
Daikin Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.