Shut-Down Procedure; Water Trap Bleed - Wittke StRLight Operator's Manual

Front-loader garbage truck
Table of Contents

Advertisement

Shut-Down Procedure

To shut down your W
Park the vehicle on solid, level ground.
1.
Set the parking brake.
2.
Ensure all hydraulic cylinders are collapsed (arms up, forks down, tailgate closed, top door
3.
closed, packer blade in "home" position).
Turn off the optional auto neutral feature, if you were using the right-hand side driving position.
4.
Turn off the hydraulic pump.
5.
The pump switch on the control panel will turn blue, indicating that the hydraulic system is
disabled.
Turn off all lights (work lights, strobe light, etc.).
6.
Shut the unit off following the chassis manufacturer's recommendations.
7.
Drain air from all air tanks.
8.
Turn off the master switch (see Figure 4-13).
9.
Figure 4-13
Master switch

Water Trap Bleed

Usually located on the right-hand side truck frame, near mid-section, the water trap bleed (see Figure
4-14) must be drained at the end of every working day. Just slacken off both water trap bleed screws
under the bowls and catch the water and oil that flow out with a rag. The water trap helps keep
moisture out of the air system.