Section 4: Maintenance
Filter Replacement
Procedure
4-10
The two filters located at the front and left side of the projector should be replaced
whenever the lamp is replaced. If you are working in an extremely dusty
environment you may want to replace the filters sooner. Use the filters provided in
the Christie approved Lamp and Filter Kit for your specific projector model.
1. TURN OFF THE PROJECTOR, COOL and UNPLUG
Before removing or installing a filter, turn off the projector and allow it to cool for
five minutes before unplugging.
2. REMOVE FILTER ACCESS
PANELS
Loosen the captive screw(s) on the filter
access panels using a #2 Phillips
screwdriver. (Front access panel located
to the left of the lens – one screw. Left
side access panel – three screws. See
Figure 4.6.)
3. REPLACE FILTERS
Pull the old filters out of the projector and discard. Do not reuse filters. Insert the
new filters with the wired side in. See Figure 4.7.
4. REPLACE ACCESS PANELS
Replace the two (2) filter access panels and tighten the screws loosened in step 1.
Figure 4.6. Remove Filter Access Panels
Figure 4.7. Insert New Filters
Mirage S+/HD, Matrix S+/HD, Christie HD/DS/DW, DLV User's Manual
020-100001-04 Rev. 1 (12/07) - Software v1.6g or higher