Mirage S+/HD, Matrix S+/HD, Christie HD/DS/DW, DLV User's Manual
020-100001-04 Rev. 1 (12/07) - Software v1.6g or higher
8. REPLACE THE LAMP DOOR
Replace the lamp door and secure it with the two (2) screws removed in Step 2.
IMPORTANT: The lamp module is calibrated for maximum performance and
brightness in this projector. Do not attempt to re-align or adjust the lamp module.
9. RECORD THE SERIAL NUMBER OF THE NEW LAMP
•
Plug in the projector and power it up.
•
In the Lamp menu, select "Change Lamp".
•
In the Lamp S/N text box, enter the serial number.
•
Press to record the number and to reset the lamp timer. The timer will now
begin to log time for the new lamp.
Lamp
Lamp Hours
Lamp S/N
1.
Lamp Message
2.
Lamp Limit
3.
Lamp Mode
4.
Power
5.
Intensity
6.
Optical Aperture
7.
Lamp History
8.
Change Lamp
IMPORTANT: If you neglect to enter a serial number, the lamp timer will not
reset to "0" and will therefore be inaccurate. The lamp life limit may then expire
prematurely.
0
?
1000
Power
500
0
New serial# entry
3
automatically updates
Lamp History...
Lamp S/N
Section 4: Maintenance
Lamp History
S/N
5679
...and resets Lamp
1234
Hours to "0"
Hours
1001
0
4-9