Alarm Menu; Trigger Field - Motorola DSR-6100 Operator's Manual

Motorola dsr-6100 commercial integrated receiver transcoder
Hide thumbs Also See for DSR-6100:
Table of Contents

Advertisement

Alarm Menu

This menu allows the user to set up different bypass modes in case the DSR-6100
goes into an alarm condition. Press the  button until the Alarm menu is located
(shown below).
The alarm can be activated for any of the following conditions:

Trigger Field

The Trigger field allows the user to select the trigger condition to activate an alarm
on the IRD. When the alarm is activated, the Alarm LED illuminates and the alarm
relay indicates an alarm condition.
Press the 4 button until the cursor is at the Trigger label, and press the ENTER
button to move into the field. Press the  buttons to display the five options:
Press the ENTER button to select the option shown and exit the field.
DSR-6100
The DSR-6100's tuner loses lock when the input is RF.
The DSR-6100 cannot lock to the ASI input when the input is ASI.
The DSR-6100 is unable to render video.
The DSR-6100 is not authorized to access the selected service.
The DSR-6100 loses power.
The DSR-6100 GigE Port Link state is inactive when the Input field
(described on page 25) is set to GigE In.
Disabled
Auto
No Signal
No Video
No Auth (Authorization)
Default: Auto
Disables any trigger for an IRD alarm.
Enables all triggers for an IRD alarm.
Alarm is triggered when the IRD loses the
incoming signal.
Alarm is triggered when the IRD loses video input.
Alarm is triggered when the IRD is not authorized
to access a selected service.
33