3

Bypass Field

Test Field

34
Press the 4 button until the cursor is at the Bypass label, and press the ENTER
button to move into the field. Press the  buttons to display the options:
Bypassed
The Bypass mode is activated and the DSR-6100 loops through
the auxiliary video and audio inputs regardless of DigiCipher II
system service authorization status. The Bypass LED on the front
panel is always lit when the DSR-6100 is in the bypass state.
Disabled
The DSR-6100 ignores the auxiliary inputs for video and audio
and attempts to output the satellite data, regardless of
authorization status.
Alarm
The DSR-6100 automatically switches to the bypassed state if
it enters the alarm condition. At such time, the Aux Video and
Audio inputs are routed to the IRD output, and the front panel
Bypass LED is lit. When the DSR-6100 exits the alarm
condition, the unit switches back to satellite video and audio.
Press the ENTER button to select the option shown and exit the field.
Note: The Test field returns to the default value (Off) when the field is exited.
The Test field provides an IRD alarm test when this field is set to On. Press the
 buttons to display the two options: Off or On.
Caution: Selecting the alarm test function with the Bypass Field set to Alarm
causes the satellite Video and Audio to be bypassed. This may result in a service
outage when the analog video and audio outputs to the cable plant.
Press the ENTER button to select the option shown and exit the field.
Default: Disabled
Default: Off