Automatic Restart After Instantaneous Power Failure (Pr. 57, Pr. 58, Pr. 162 To Pr. 165) - Mitsubishi Electric FR-A520-0.4K -55K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Table of Contents

Advertisement

z

Automatic restart after instantaneous power failure (Pr. 57, Pr. 58, Pr. 162 to Pr. 165)

Pr. 57 "coasting time for automatic restart after instantaneous power
failure/commercial power supply-inverter switch-over"
Pr. 58 "cushion time for automatic restart after instantaneous power
failure/commercial power supply-inverter switch-over"
Pr.162 "Automatic restart after instantaneous power failure selection"
Pr.163 "First cushion time for restart"
Pr.164 "First cushion voltage for restart"
Pr.165 "Restart stall prevention operation level"
You can restart the inverter without stopping the motor (with the motor coasting) when the commercial
z
power supply is switched to the inverter operation or when the power is restored after an instantaneous
power failure. (When automatic restart operation is set to be enabled, UVT and IPF among the alarm
output signals will not be output at occurrence of an instantaneous power failure.)
Parameter
Factory Setting
Number
57
9999
58
1.0 s
162
0
163
0 s
164
0%
165
150%
Voltage
Pr.164
(Pr.163)
Voltage rise time
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting Range
0, 0.1 to 5 s, 9999
0 to 60 s
0: Frequency search, 1: No frequency
0, 1
search
0 to 20 s
0 to 100%
0 to 200%
NFB
MC1
Pr.58
Time
85
PARAMETERS
Remarks
9999: No restart
MC2
×
MC3
R 〈L
U
1
S 〈L
V
2
T 〈L
W
3
R1 〈L
11
S1 〈L
21
STF
CS
SD
MC switching sequence
Connect CS-SD for use of only
CS
automatic restart after instantaneous
SD
power failure.
IM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents