Acceleration/Deceleration Reference Current/Lift Mode Starting Frequency (Pr. 61 To Pr. 64) - Mitsubishi Electric FR-A520-0.4K -55K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Table of Contents

Advertisement

z

Acceleration/deceleration reference current/lift mode starting frequency (Pr. 61 to Pr. 64)

Pr. 61 "reference current"
Pr. 62 "reference current for acceleration"
Pr. 63 "reference current for deceleration"
Pr. 64 "starting frequency for elevator mode"
Set these parameters to improve performance in the intelligent mode.
z
Parameter
Factory Setting
Number
61
9999
62
9999
63
9999
64
9999
<Setting>
( 1 ) Pr. 61 "reference current setting"
Setting
9999 (factory setting)
0 to 500A
( 2 ) Pr. 62 "reference current for acceleration"
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 3 ) Pr. 63 "reference current for deceleration"
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 4 ) Pr. 64 "starting frequency for elevator mode"
Setting
9999 (factory setting)
0 to 10Hz
Note: Pr. 61 to Pr. 64 are only valid when any of "1 to 6" is selected for Pr. 60.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pr. 60 "intelligent mode selection"
Setting Range
9999: Referenced from rated inverter
0 to 500A, 9999
current.
0 to 200%, 9999
0 to 200%, 9999
0 to 200%, 9999
Reference Current
Referenced from rated inverter current
Referenced from setting (rated motor current)
Reference Current
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
Reference Current
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
Reference Current
2Hz is the starting frequency.
The setting of 0 to 10Hz is the starting frequency.
90
PARAMETERS
Related parameter
Remarks
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode