Inboard Dedicated Options - Mitsubishi Electric FR-A520-0.4K -55K Instruction Manual

Transistorized inverter, high function & low acoustic noise
Table of Contents

Advertisement

7.1.2 Inboard dedicated options

„ Inboard options
Name
Type
12-bit digital input
FR-A5AX
Digital output
FR-A5AY
Extension analog
output
Relay output
FR-A5AR
Orientation, PLG
output (Note 3)
FR-A5AP
Pulse train input
Computer link
FR-A5NR
Relay output
Profibus DP
FR-A5NP
Device Net
FR-A5ND
TM
CC-Link (Note 2)
FR-A5NC
Modbus Plus
FR-A5NM
Note: 1. Three inboard options may be mounted at the same time (the number of the same options
mountable is only one, and only one of the communication options may be mounted.)
2. CC-Link stands for Control & Communication Link.
3. The FR-A5AX (12-bit digital input) is required for orientation control.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
z
Input interface used to set the inverter frequency accurately using external 3-digit BCD or
12-bit binary-coded digital signals.
z
Gains and offsets can also be adjusted.
z
Among 26 standard output signals of the inverter, this option outputs any 7 selected
signals from open collector output terminals.
z
Outputs extra 16 signals which can be monitored on the FM and AM terminals such as
output frequency,
20mADC or 5V(10V)DC meter can be connected.
z
z
Among 26 standard output signals of the inverter, this option outputs any 3 selected
signals from relay contact output terminals.
z
Used with a position detector (pulse encoder) installed on a machine tool spindle to stop
the spindle in position (orientation control).
z
The motor speed is detected by the pulse encoder and this detection signal is fed back to
the inverter to automatically compensate for speed variation. Hence, the motor speed can
be kept constant if load variation occurs.
z
The current spindle position and actual motor speed can be monitored on the operation
panel or parameter unit.
z
A pulse train signal can be used to enter the speed command to the inverter.
z
Operation/monitoring/parameter change of the inverter can be performed under the control
of a user program from a computer, e.g. personal computer or FA controller, connected by
a communication cable.
z
Any one output signal can be selected from among the standard output signals of the
inverter and output as a relay contact (contactor) signal.
z
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
z
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
z
Operation/monitoring/parameter change of the inverter can be performed from a PLC.
z
Operation/monitoring/parameter change of the inverter can be performed from a computer
or PLC.
200
OPTIONS
Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents