8.2.2.11 LED INTENSITY

The ekey home CP DRM allows you to define the LED intensity of the status LED on the finger scanners in
idle mode. The status LED is always preset on „On" (factory setting) and lights up blue with maximum
intensity. Some customers however wish to have it dimmed or even switched off, so that the finger
scanner beside the front door does not attract too much attention.
DISPLA Y
START
1.) First enter the current security code as per section 8.2.2.4.
2.) Select „LED intensity" in the main menu using the
3.) Press the
button.
4.) Now select the LED status of the status LED on the finger scanner in idle mode using the
buttons.
5.) Press the
button.
The status of the status LED on the finger scanner will be changed immediately to the one you
selected and you will go back to the main menu.
© ekey biometric systems GmbH
You
can
define
here the status of
this LED when the
finger scanner is in
idle mode.
Enter sec urity
DISPLA Y
code
Enter
security
code
Select the menu item
„LED intensity"
Operating instructions ekey home
3 different statuses can be set:
LED on ... The LED lights up with full
intensity (factory setting).
LED dimmed ... The LED is dimmed.
LED off ... The LED is off.
KEY
DISPLA Y
STROKE
Select the LED
status
buttons.
KEY
DISPLA Y
STROKE
Page 36 / 41