Hardware Setup-Sensors - CCTV DN-1808S Manual For Installer And User

Table of Contents

Advertisement

1.10 Hardware Setup - Sensors
1
[Setup]
Check the box
to enable sensors. Un-
check the box to disable sensors. Sensor inputs
are standard on Rack Mount units and optional
on Desktop units. If your unit does not have
sensor inputs then do not use this function.
[NC/NO]
2
Choose sensor type. Click the button to
switch between [NC] and [NO] sensor
types.
> NC = Normally Close type. If the door/
object with the sensor installed is not
closed, the sensor will trigger.
> NO = Normally Open type. If the door ob-
ject with the sensor installed is not open, the
sensor will trigger
2
1
3
4
3
[Use alarm]
Selecting [Use alarm] will enable the built-in
internal speaker to beep if a sensor is triggered.
The speaker however will not beep if the corre-
sponding camera schedule is set to Continuous
Recording.
[Recording Time]
4
Select the number of seconds to record
when a sensor is triggered. This function
will not work if the recording schedule is
not set to Sensor or Motion
17

Advertisement

Table of Contents
loading