Rep 3 Fuser Fan - Xerox WORKCENTRE 3119 Service Manual

Hide thumbs Also See for WORKCENTRE 3119:
Table of Contents

Advertisement

REP 3 Fuser Fan

Parts list on PL 2
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the Rear Cover. (Refer to REP 2)
2. Release the harness from the Harness
Holder. Remove 1 screw, then the Har-
ness Holder, Figure 1.
Figure 1
WorkCentre 3119
3. Remove the Fuser Fan, Figure 2.
06/06
Repairs/Adjustments
Figure 2
4-5