Repairs/Adjustments

REP 9 Fuser

Parts list on PL 5
WARNING
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the Rear Cover. (Refer to REP 2)
2. Disconnect CON 1 from the SMPS/HVPS
and CN 12 from the Main PBA, Figure 1.
Figure 1
4-14
When removing the fuser, take care not to
damage the Exit Sensor.
3. Remove 4 screws, then the fuser, Figure
2.
06/06
CAUTION
Figure 2
WorkCentre 3119