Repairs/Adjustments
8. Release the Thermistor Harness, Figure
7.
Figure 7
9. Remove 1 screw, then the Thermistor,
Figure 8.
Figure 8
4-16

REP 10 LSU

Parts list on PL 1
Switch off the electricity to the machine. Dis-
connect the power cord from the customer
supply while performing tasks that do not
need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1. Remove the Scan Assembly. (Refer to
REP 6)
2. Remove the Middle Cover Unit (Refer to
REP 8)
3. Remove 1 screw, then the CAP LSU, Fig-
ure 1.