APRILIA SL 750 SHIVER Service Station Manual page 69

Hide thumbs Also See for SL 750 SHIVER:
Table of Contents

Advertisement

SL 750 SHIVER
TABLE C - MAIN CABLE HARNESS
The main cable harness is laid be-
tween the relay and the fall sensor,
under the fall sensor connector.
TABLE D - DIAGNOSIS CONNECTORS
Fasten both diagnosis connectors with
a small clamp, under the cable harness
main branch.
TABLE E - CABLE HARNESSES UNDER THE TANK
1. Fasten the pipe with two medium clamps.
2. The flywheel and side stand cables shall be laid through the cable guide screwed to the filter
housing.
3. Bunch the cables with clamps.
4. Fasten with a clamp cables on the filter housing and the rear cylinder coil.
Electrical system
ELE SYS - 11