44 - CHECK IF THERE IS VOLTAGE IN THE RED/BLACK CABLES ON THE CONTROL
RELAY (START-UP LOGIC) 40
45 - CHECK CONTINUITY AND GROUND INSULATION OF THE YELLOW/PINK CABLE
FROM THE RELAY TO THE ENGINE CONNECTOR (PIN 2)
46- RESTORE THE CABLE HARNESS - END
47 - CHECK THE CONTROL UNIT CONNECTOR
48 - RESTORE THE CABLE HARNESS - END
49 - REPLACE THE CONTROL UNIT - END
50 - PRESSING THE STARTER BUTTON, DISCONNECT THE CONNECTOR OF THE
WHITE/SKY BLUE AND WHITE/RED CABLES OF THE START-UP RELAY 36, AND
CHECK IF THERE IS VOLTAGE TO THE YELLOW/RED CABLE OF THE CONTROL RE-
LAY- START-UP LOGIC- 40
51 - REPLACE THE RELAY - END
52 - PRESSING THE STARTER BUTTON, CHECK IF THERE IS VOLTAGE TO THE YEL-
LOW/RED CABLE OF THE START-UP RELAY
53 - REPLACE THE RELAY - END
54 - CHECK IF THE BLUE CABLE OF THE START-UP RELAY 36 IS GROUNDED
55 - RESTORE THE CABLE HARNESS -END
56 - WITH THE KEY TURNED TO "OFF" CHECK IF THERE IS VOLTAGE TO THE REAR
RED CABLE (WITH PROTECTION COVER) OF THE START-UP RELAY 36
57 - RESTORE THE CABLE HARNESS -END
58 - PRESSING THE STARTER BUTTON, CHECK IF THERE IS VOLTAGE TO THE
FRONT RED CABLE OF THE START-UP RELAY 36
59 - RESTORE THE CABLE HARNESS
60 - CHECK CONTINUITY OF THE RED CABLE BETWEEN THE START-UP RELAY 36
AND THE STARTER MOTOR
YES, go to 50; NO, go to 51
OK, go to 47; NOT OK, go to 46
OK, go to 49; NOT OK, go to 48
OK, go to 52; NOT OK, go to 53
OK, go to 54; NOT OK, go to 55
OK, go to 56; NOT OK, go to 57
OK, go to 58; NOT OK, go to 59
OK, go to 60; NOT OK, go to 61
YES, go to 62; NO, go to 63