• If you need to set the SSID, the SSID window appears. Go to
Figure 35

SSID window

• If the SSID setting is not necessary, the Add LU window closes, and the LU Operation pane
appears. Settings appear in blue italics in the Device tree and Device list. Contents specified in the
Add LU window appear in the Preset list. To check setting details, right-click the setting in the Preset
list, and select Detail. To cancel settings, right-click the setting in the Preset list, and select Delete.
Go to
step
13.
10.If you need to set an SSID to the mapped internal XP LDEV, the SSID pane appears. When storage is
partitioned using XP Disk/Cache Partition, select the SLPR number in the SLPR box. If you select the
Limited check box and select the SLPR number, you can set only SSIDs that can be used for the selected
the SLPR. If you do not select the Limited check box, you can set the SSID from all unused SSIDs
regardless of the selected SLPR number. Right-click the CU:LDEV number on the SSID pane, and select
Set SSID. The Set SSID window appears.
Figure 36

Set SSID window

11.Enter the SSID. If you selected the Limited check box on the SSID window, only SSIDs that can be used
in the SLPR selected on the SSID pane appear in the drop-down list. If you did not select the Limited
check box on the SSID pane, all unused SSIDs appear in the list, regardless of the selected SLPR. You
can enter 0x0004 to 0xFFFE as an SSID.
12.Click OK. The Set SSID window closes, and the LU Operation pane appears.
Settings appear in blue italics in the Device tree and Device list and also appear in the Preset list. To
check setting details, right-click the setting in the Preset list, and select Detail. To cancel settings,
right-click the setting in the Preset list, and select Delete.
13.Click Apply. A confirmation message appears.
If you have already stopped the application, go to
click Cancel to close the message pane, stop the application, and retry the operation.
14.Click OK.
The mapping set in the Add LU window is applied to the local disk array, and the specified contents
appear in the Device list.
If errors occur during the external LU mapping operation, failed settings and error codes appear in the
Preset list. To check error messages, right-click the failed setting, and select Detail.
step
10.
step
14. If you have not stopped the application,