Path Status And Examples Of Recovery Procedures (Thunder 9500V Subsystems) - HP StorageWorks User Manual

External storage xp
Hide thumbs Also See for StorageWorks:
Table of Contents

Advertisement

Path status and examples of recovery procedures (Thunder 9500V subsystems)

Table 15
shows examples of recovery procedures when the path status is not normal. When the path status
is not normal, see
status. If you cannot restore the path, contact you HP account support representative.
Table 15

Path status and examples of recovery procedures (Thunder 9500V subsystems)

Path status
External device setting changed
Illegal request
Response error
Cannot detect port
104 External Storage XP for the XP12000/XP10000
"Troubleshooting External Storage
Examples of recovery procedures
LUN Manager may have changed the LU paths' settings.
Check the LU paths' settings. If the LU paths' settings changed, change the
settings back to the ones used when the volume was mapped. Or use
External Storage XP to perform the Delete LU operation, and perform the
Add LU operation again.
Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the
access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,
Continuous Access XP, or another copy program. If the volume is set as a
pair volume, the volume might be protected because of the pair status. If
the volume is protected, change the pair status or delete the pair.
Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the
access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,
Continuous Access XP, or another copy program. If the volume is set as a
pair volume, the volume might be protected because of the pair status. If
the volume is protected, change the pair status or delete the pair.
Open LDEV Guard may have changed the volume's access attribute.
Check the volume's access attribute. If the volume is protected by the
access attribute, release the protection.
There is a problem with the connection to the external disk array. The
following are possible causes:
The fibre cable is not connected properly.
The topology setting between the external and target ports does not
match.
If the external disk array is connected through switches, the switches'
settings might not be appropriate.
Check if the fibre cable is connected properly, and use LUN Manager to
set the fibre channel port properly.
LUN Manager may have enabled host group security.
Check if host group security is enabled. If host group security is enabled,
disable host group security.
XP" on page 95 and this table to recover the path

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks and is the answer not in the manual?

Questions and answers

Table of Contents