Adding New Logical Paths From The Connected Mcu To An Existing Rcu; Deleting Paths From The Connected Mcu To An Existing Rcu; Adding And Deleting Ssids For Rcus (Add Ssid/Delete Ssid) - HP xp12000 User Manual

Continuous access xp
Hide thumbs Also See for xp12000:
Table of Contents

Advertisement

NOTE:
Maximum number of paths is eight. Each item has seven fields to enter paths, but you cannot enter
more than eight paths.
See
Table 22

Adding new logical paths from the connected MCU to an existing RCU:

Before adding a path to an RCU, ensure that the remote copy connection is properly installed, appropriate
MCU ports are configured as Initiator ports (fibre) or RCPs (serial), and appropriate MCU CU image is
selected. You can add up to four RCUs to each MCU CU image and establish up to eight paths to each
RCU. When you add a path to an RCU, Continuous Access XP automatically starts using the new path to
perform Continuous Access XP copy activities.
1.
From the CU Number/Port tree on the RCU Operation pane, ensure that the correct CU image is
selected.
2.
From the MCU/RCU list, click the RCU.
3.
Right-click, and click Edit SSID(s)&Path(s).
4.
Right-click, and click Add Path. The Add Path pane appears.
5.
Enter new paths. Each item has seven fields to enter, but you can only enter the number of paths left
(maximum number of paths is eight).
6.
Click Set to set the paths. The list changes to the Path Settings Parameter list.
NOTE:
deleting
7.
Click Apply on the Continuous Access XP main pane to apply the settings to the disk array. The MCU
automatically begins using the new logical path for Continuous Access XP activities.

Deleting paths from the connected MCU to an existing RCU:

Before deleting a path to an RCU, ensure that remaining number of paths is equal to or greater than
minimum number of paths setting (selected on the RCU Option pane). The delete path operation fails if
number of remaining paths is less than minimum number of paths.
1.
Open the RCU Option pane, and check the minimum number of paths setting. If the remaining number
of paths is less than this value, the delete path operation will fail. If needed, change the minimum
number of paths so you can delete the path.
2.
From the CU Number/Port tree on the RCU Operation pane, ensure that the correct CU image is
selected.
3.
From the MCU/RCU list, click the RCU from which you want to delete the path.
4.
Right-click, and click Edit SSID(s)&Path(s).
5.
Right-click, and click Delete Path. The list changes to the Path Settings Parameter list. Only selected
RCUs are listed.
NOTE:
deleting
6.
Click Apply on the Continuous Access XP main pane to apply the deletion to the disk array.

Adding and deleting SSIDs for RCUs (Add SSID/Delete SSID)

Before adding an SSID, ensure that the remote copy connection is properly installed. You can add three
SSIDs to each RCU. Before deleting an SSID, ensure that the remaining SSIDs are valid, or the connection
between the MCU and RCU may be lost.
74
Continuous Access XP for the XP12000/XP10000
on page 65 for further information about path status.
After being set, options can be modified and canceled (see
settings" on page 77).
After being set, options can be modified and canceled (see
settings" on page 77).
"Modifying parameters and
"Modifying parameters and