If an error occurs, the failed setting and an error code appears in the Preset list.
Figure 30
Error when changing port attribute
To view error messages, right-click the failed row, and select Detail.
6.
Set the topology for the connection configuration.
When an FC switch is connected, set Fabric to Enable. When a switch is not connected, set Fabric to
Disable, and specify FC-AL. Set Connection according to the actual connection configuration. For more
information about setting the topology, see the HP StorageWorks LUN Configuration and Security
Manager XP user guide for the XP12000/XP10000.
7.
Set the channel transfer speed to Auto Negotiation.
Mapping external LUs (Add LU)
After setting the port used for External Storage XP to External, map the external LU as an internal XP LDEV.
If you mapped the external LU and previously set the VMA of LUN Security XP Extension in that volume, the
former VMA setting is overwritten when you map the volume again. However, if LUN Security XP Extension
is not installed when you remap the volume, the volume with the VMA setting cannot be mapped.
The following are the mapping operations:
• "Mapping external LUs individually (Add
• "Mapping multiple external LUs at one time (Add LU
• "Displaying detailed information stored in VMA (VMA
Mapping external LUs individually (Add LU)
This section describes mapping operations starting with the Add LU command. Use the Add LU
Select Paths
(Figure
individually.
60
External Storage XP for the XP12000/XP10000
32), SSID
(Figure
35), and Set SSID
LU)" on page 60
(Auto))" on page 68
information)" on page 73
(Figure
36) panes for mapping external LUs
(Figure
31),
Need help?
Do you have a question about the StorageWorks and is the answer not in the manual?