Overheat Warning Indicator - Yamaha WaveRunner XLT1200 Service Manual

Hide thumbs Also See for WaveRunner XLT1200:
Table of Contents

Advertisement

+
ELEC
INDICATION SYSTEM

Overheat warning indicator

1. Check:
Overheat 1 warning indicator
Not operating → Replace the multi-
function meter.
Checking steps:
Supply DC 12 voltage to the natural
six-pin connector (+: red, –: black) with
a battery.
Connect the gray/black and black ter-
minals with a jumper lead 1.
Connect the green and red terminals
with a jumper lead 2.
Make sure the water temperature
warning indicator 3, "
sage 4 and "WARNING" lamp 5
blink, and the buzzer sounds intermit-
tently.
7-42
E
" mes-