Ac Generator No-Load Performance (Dr350S); Ac Generator Stator Coil (Dr350S); Regulator/Rectifier (Dr350S) - Suzuki DR350 Service Manual

Dr350; dr350s
Hide thumbs Also See for DR350:
Table of Contents

Advertisement

8·29 DR350S
AC GENERATOR
NO·
lOAD PERFORMANCE
Remove the
seat.
Disconnect the
AC generator
lead
wire coupler.
Start the
engine and keep it
runn
ing
at 5 000 r/min.
Measure the AC
voltage
between the three
ye llow
lead
wires with
the pocket tester.
If
the tester
reads
under
65 V.
the AC generator is
faulty.
STD No -load performance
:
More than 65V lAC)
at
5 000
r/min
09900-25002
: Pocket
tester
AC GENERATOR
STATOR COil
Using the pocket
tester,
check
the
continuity
between
the
lead wires of the
stator.
Also check that
the
stator core
is
insu lated.
STD
resistance:
0.1
-
1
.3
n
09900-25002
:
Pocket
tester
NOTE:
When making
this
test,
it is
not necessary to
remove
the AC
generator.
REGULA TOR/RECTIFIER
Remove the seat.
Disconnect the
lead wires.
,
,
(
3
3
\
"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr350s

Table of Contents