Additional Connector Information

TP connectors
All LAN ports, whether on XTP boards or the switcher Ethernet port use
Category (CAT) 5e, CAT 6a, or CAT 7 unshielded twisted pair (UTP) or
shielded twisted pair (STP) cables.
The XTP ports are compatible with Extron XTP DTP 24 SF/UTP cables,
as well as CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP, SF/UTP, and
S/FTP) and unshielded twisted pair (U/UTP) cable.
Both TP cable types are terminated with RJ-45 connections. Cables are
limited to a length of 330 feet (100 m).
NOTES:
For XTP connections, Extron recommends 24 AWG, solid
conductor, shielded cable, with a minimum bandwidth of
250 MHz.
Do not stretch or bend cables. Transmission errors can occur.
The switcher LAN port and the LAN ports on the input and output
boards support both 10 Mbps (10Base-T — Ethernet) and 100 Mbps
(100Base-T — Fast Ethernet), half-duplex and full-duplex Ethernet
connections. Both Ethernet speeds require CAT 5e cable at minimum.
The TP cable can be terminated as a straight-through cable or a
crossover cable for the LAN port and must be properly terminated for
your application (see figure 4).
Crossover Cable
Pins:
12345678
End 1
Pin
Wire color
Wire color
1
White-green
White-orange
2
Green
Orange
3
White-orange
White-green
4
Blue
Blue
5
White-blue
White-blue
6
Orange
Green
7
White-brown
White-brown
8
Brown
Brown
Insert Twisted
Pair Wires
T568A
RJ-45
A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
Connector
reversed) is a "crossover" cable.
Figure 4.
RJ-45 Connector and Pinout Tables
Switcher and XTP board LAN cables
The LAN ports require CAT 3, CAT 5e, or CAT 6a, crossover or patch
cables.
12
XTP CrossPoint 1600 and 3200 • Installation
Straight-through Cable
End 2
End 1
End 2
Pin
Wire color
Wire color
1
White-orange
White-orange
2
Orange
Orange
3
White-green
White-green
4
Blue
Blue
5
White-blue
White-blue
6
Green
Green
7
White-brown
White-brown
8
Brown
Brown
T568B
T568B
T568B
A cable that is wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.
XTP board XTP cables
ATTENTION:
Do not connect these boards to a computer data or
telecommunications network.
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP
cable or STP201 cable to link the XTP products.
To ensure FCC Class A and CE compliance, STP cables and
STP connectors are required.
Extron recommends using the following practices to achieve full
transmission distances up to 330 feet (100 m) and reduce transmission
errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for
the best performance:
XTP DTP 24/1000
Non-Plenum 1000' (305 m) spool
XTP DTP 24P/1000 Plenum 1000' (305 m) spool
XTP DTP 24 Plug
Package of 10
If not using XTP DTP 24 cable, at a minimum, Extron recommends
24 AWG, solid conductor, STP cable with a minimum bandwidth of
400 MHz.
Terminate cables with shielded connectors to the TIA/EIA T568B
standard only (patch cables, see
figure 4
Limit the use of more than two pass-through points, which may include
patch points, punch down connectors, couplers, and power injectors.
If these pass-through points are required, use CAT 6 or 6a shielded
couplers and punch down connectors.
:
NOTE
When using cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 m, where cables are
straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook and
loop fasteners.
Separate twisted pair cables from AC power cables.
XTP CrossPoint 1600 and 3200 • Installation
22-236-03
22-235-03
101-005-02
on the previous page).
13