Number Of Connections; Establishing A Usb Port Connection; Host-To-Switcher Instructions; Common Sis Command Symbols - Extron electronics XTP CrossPoint 1600 Setup Manual

Configurable digital video matrix switchers
Hide thumbs Also See for XTP CrossPoint 1600:
Table of Contents

Advertisement

2.
If necessary, enter the appropriate password.
If the password is accepted, the switcher responds with Login User
or Login Administrator .
If the password is not accepted, the Password prompt reappears.

Number of connections

A switcher can have up to 200 simultaneous TCP connections, including
all HTTP sockets and Telnet connections. When the connection limit is
reached, the switcher accepts no new connections until some have been
closed. No error message or indication is given that the connection limit
has been reached. To maximize the performance of your switcher, keep
the number of connections low and close unnecessary open sockets.

Establishing a USB Port Connection

A standard USB cable and the Extron DataViewer utility, version 2.0 or
newer, can be used for connection to the XTP CrossPoint matrix switcher
Configuration port. The USB cable, available at any local electronics
store, should be terminated on one end with a mini USB B male
connector.
NOTE:
Before you use the USB port for the first time, install the
USB driver on your computer. The simplest way to do this is to
install version 8.0 or newer of the XTP System Configuration
software and then run the Found New Hardware Wizard.

Host-to-Switcher Instructions

The switcher accepts SIS commands through its serial port, its USB port,
or its LAN port. SIS commands consist of one or more characters per
command field. They do not require any special characters to begin or
end the command character sequence. Each switcher response to an
SIS command ends with a carriage return and a line feed (CR/LF =
which signals the end of the response character string. A string is one or
more characters.
NOTE:
The tables that begin on the next page are a partial list of SIS
commands. For a complete listing, see the XTP CrossPoint 1600
and 3200 Series User Guide.

Common SIS Command Symbols

The following symbols are used throughout the command and response
page
tables, which start on
= Space
= Carriage return and line feed
]
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
E
= Escape key (hex 1B)
W
= Can be used interchangeably with the
22
XTP CrossPoint 1600 and 3200 • Remote Control
]
24:
}
character)
E
character

Arrangement of Command and Response Tables

The following pages present five command and response tables, each
defining a subset of SIS commands and their responses, with examples
where appropriate. The following tables are presented:
),
SIS Command and Response Table for Matrix Switcher
Commands, starting on the next page — SIS commands to control
and monitor the XTP CrossPoint switcher itself
SIS Command and Response Table for XTP T
page 33 — SIS commands to control and monitor the XTP T HDMI
transmitter endpoint from the matrix switcher
SIS Command and Response Table for XTP R HDMI and
XTP SR
HDMI, starting on page 35 — SIS commands to control and
monitor the XTP R HDMI and XTP SR HDMI receiver endpoints from
the matrix switcher
SIS Command and Response Table for XTP T USW
starting on page 38 — SIS commands to control and monitor the
XTP T USW 103 switcher endpoint from the matrix switcher
SIS Command and Response Table for IP-Specific
starting on page 41 — SIS commands to control and monitor the IP
interface of the XTP CrossPoint matrix switcher
XTP CrossPoint 1600 and 3200 • Remote Control
HDMI, starting on
103,
Commands,
23