8. Cabling requirements

9
8
Legend
1a. 220-240V AC mains cable via mains isolator
1b. Low-voltage 16V AC battery charger supply
2. Intercom cable (n1 + 6 core) to house.
3. Master motor (MTR M) or Slave motor (MTR S) cable ( minimum, 2 core 2mm +
4 core 0,5mm² multi-stranded) see note
4. Optional radio receiver cable (3 core 0,5mm multi-stranded, optional)
5a. Optional pedestrian key-switch (2 core 0,5mm multi-stranded).or
5b. Optional keypad (3 core 0,5mm multi-stranded).
6. Optional infrared beams or safety edge (3 core 0,5mm multi-stranded or 4 core
0.5mm² for CE compliance.)
7. Optional intercom cable (n2+2 core 0,5mm² multi-stranded) to gate station
8. Optional electric lock (2 core 0.5mm²)
9. Optional pillar light cable (3 core, size according to power reg.)
10.
Optional ground loop for free-exit (1core 0.5mm multi-stranded - silicone-coated)
Mains isolator must be fitted less than 1m from controller
Increase cable thickness if Pillar Lights are to be installed.
Screened cable is always recommended to provide better protection against lightning - earth one end of screening.
Domestic charger only.
For optimum range an external receiver can be mounted on the wall.
CENTSYS has available custom VECTOR2 cable order reference: CABLEVEC68
Consult manufacturer of loop detector for specific details
All cables must be routed in conduit unless underground cable is being used
Mains isolator must be less than 1m from the operator
Safety beams are always recommended
7
5
2
1 1
6
5
2
FIGURE 19. CABLING REQUIREMENTS
switch (3 core LNE 0,5mm²), or
(2 core 1,5mm²).
2
2
2
2
Page 20