8. Unlock the operator and swing the gate
closed.
9. Remove the pin and the operator from the
bracket, check that there are at least one
or two turns of the actuator before it is fully
extended.
If it becomes obvious that the
operator does not have enough
stroke, reduce either the A or B
distances by moving the wall
Be sure not to make the A and B
values less than allowed for in the
installation tables on page 26 and 27.
In general:
• Large B distances give good security and
good closing push force.
• Small A and small B will increase the
speed.
Fasten gate bracket to gate
10. Secure the gate bracket using the most
appropriate means.
It is critical that the gate bracket is
securely mounted.
See page 15 for site considerations.
11. Fit operator, wall bracket pins and snap
As an alternative to the snap ring, fit
a padlock.