19. Charger and Pillar Light connections

220
E
-240V AC
N
L
Mains in
Protection fuse on
mains input to
charger (rating:
250mA slow blow)
Fuse protection
The following protection fuses are provided on the system:
Item
Main controller
Motor Circuit - fuse per channel
Light circuit
Auxiliary supply
CHARGER
Mains Input
To reset: Power off controller for at least one minute and re-apply power.
Auxiliary
supply
Pillar
Light
Neutral
Live
FIGURE 5. CHARGER AND PILLAR LIGHT CONNECTIONS
Type
Automotive Fuse (25X7)
5X20mm
Electronic fuse - not replaceable
5x20mm
Page 41
S Sens1
S Sens2
M Sens1
M Sens2
Sens+
Sens-
Safe CLS
Safe OPN
Com
LCK/STP
TRG
PED
Com
FRX
LIT
LED
Com
Aux 12V
Safe Com
Sol
Light
Light
Batt +
Batt -
MTR M+
MTR M -
MTR S+
MTR S -
Rating
15A
3A Fast Blow
3A
250mA Fast Blow