Centsys VECTOR2 Installation Manual page 58

Linear swing gate operator
Table of Contents

Advertisement

Mode C will turn on the courtesy light during the pre-opening and pre-
closing delays, as well as while the gate is moving
In these pre-flashing modes, the timed courtesy light functionality is not
available
Menu 10 - General features
Operating standard
Regional operating standards can be set. Applying this setting will
automatically configure the controller settings to conform to the specific
regions standard (e.g. UL325 or CE)
Reset options
The controller settings can be reset through the reset options menu. Various
reset options are available:
Factory defaults – All settings will be restored to the default values
dictated by the operating standard/profile that is currently selected. All
remote controls and gate limits will not be affected
Delete all remotes - Delete all the remotes stored in the system, no
settings affected
Reset all – Clears and defaults the system completely. Unit will be reset to
the factory default settings in addition to clearing all remotes and time
periods
Diagnostic screen
Allows a diagnostic screen to be displayed. This can be useful when
troubleshooting, but requires some technical knowledge
Round test button
Allows the round test button on the controller to be disabled, in cases where
higher security is required
Menu 11 - Remote controls
The controller is capable of learning up to 64 CENTSYS NOVA remote controls /
transmitters. Each transmitter can have up to four buttons. Each transmitter
learned into the system is assigned a unique transmitter ID
It is possible to artificially increase the number of buttons of a multi-
button transmitter by using a two button combination
One of the buttons is used as a shift button to allow the other
buttons to be used again in combination with this button. In other
words the user will press and hold the shift button, before pressing
one of the other buttons to create a new button
The shift button cannot be used as a button on its own, it must always
be used in combination with the other buttons
Benefits of the shift button system:
Use of the shift button system allows a three button transmitter to
gain an extra button and operate four functions and likewise a four
button transmitter gains two extra buttons and can operate six
functions