Centsys VECTOR2 Installation Manual page 52

Linear swing gate operator
Table of Contents

Advertisement

Short Stop value
The Short Stop distance can be set
between 1mm and 40mm of piston
stroke.
PCM push force
The amount of force applied by the
actuator when in PCM can be set as
a value from 1 to 15
Leaf delay
Leaf delay is used in cases where
one gate leaf must move before the
other. The most common need for
this arises when a mechanical 'lip' is
fitted to one of the gates. In a
double leaf installation, a leaf delay
can be set whereby the M motor will
open before the S motor, and the S
motor will close before the M motor
Leaf delay value
The leaf delay is based on piston
position, and can be adjusted from
3mm to 250mm of piston travel.
Pre-open delay
Allows a delay between a valid
trigger signal being received and
the gate commencing movement in
the opening direction. A warning
light can be set to activate during
this delay. (Refer to Pre-flash
modes of the feature, for more
details). This setting applies to both
motors
Pre-close delay
Allows a delay between a valid trigger signal being received and the gate
commencing movement in the closing direction. The delay will also occur if the
gate is set to close automatically. A warning light can be set to activate during
this delay. (Refer to Pre-flash modes of the feature 'Pillar Light', for more
details). This setting applies to both motors
Opening speed
Sets the maximum piston opening speed in millimeters per second.
This setting applies to both motors
Closing speed
Sets the maximum piston closing speed in millimeters per second. This setting
applies to both motors
S Gate closes first
Line of gates when closed
*
*
S Gate stops slightly before closed position
M Gate engages with S Gate
With PCM, Master Gate continues closing,
*
pushing the Slave Gate with it
If "Short Stop" is correctly set, PCM will cut off
when gates reach closed position, in line
Page 48
Mechanical lip
M gate closes
slightly behind
S Gate (Leaf delay)
FIGURE 63.
M Gate continues to close
"Short Stop"
FIGURE 64.
Mechanical lip on
*
FIGURE 65.
FIGURE 66.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vector2 400Vector2 500

Table of Contents